This is a V-type high efficiency air filter from Zanxis, designed with a V-bank structure to deliver high airflow at low resistance. It filters airborne particles across efficiency classes M6 to H14, using high-performance glass fibre media. It is intended for cleanrooms, GMP manufacturing, hospitals, semiconductor fabs, gas turbine intakes, and commercial AHU systems where verified performance matters.
| Item | Detail |
|---|---|
| Product name | V-Bank / V-Cell Medium & HEPA Filter |
| Filter efficiency | M6 / F7 / F8 / F9 / E10 / E11 / H13 / H14 |
| Core media | High-quality ultra-fine glass fibre filter paper |
| Frame material | ABS high-strength plastic / galvanized iron |
| Rated operating air velocity | 2.5 m/s (for high-airflow, high-throughput systems) |
| Typical applications | Pharmaceutical GMP workshops, semiconductor cleanrooms, hospital operating theatres, gas turbine intake systems, commercial building central AHU |
| Common size reference (W × H × D) | 24×24×12 in (592 × 592 × 292 mm); 20×24×12 in (490 × 592 × 292 mm); 12×24×12 in (287 × 592 × 292 mm) |
| Certification and customisation | Own CNAS-accredited testing centre; ISO 9001, IATF 16949 certified; full OEM customisation of non-standard sizes, efficiencies, and airflow. |
Before specifying a V-bank filter, it is good practice to verify several parameters. First, confirm the required efficiency class (M6 to H14) and the test standard it is based on. Second, check the rated airflow at 2.5 m/s and the corresponding initial resistance, as these determine fan energy consumption. Third, verify the external dimensions and frame material against your installation space. Fourth, confirm the dust holding capacity if long service life is a priority. Zanxis can provide test data for these values and assist in matching the filter to your system.
We recommend a structured approach to sample validation, especially for critical applications. The typical workflow is:
This process helps ensure that the delivered filters match the validated performance.
The Zanxis V-type filter features a V-bank configuration that increases media area within a compact frame, allowing high airflow capacity at low pressure drop. The media is high-quality ultra-fine glass fibre paper, chosen for its particle capture efficiency and consistent performance. The frame is available in ABS high-strength plastic or galvanized iron, providing structural rigidity under high airflow. The filter is rated for an operating velocity of 2.5 m/s, making it suitable for high-throughput systems such as those in semiconductor manufacturing and large AHUs. Typical installations include pharmaceutical GMP cleanrooms, hospital operating theatres, gas turbine intake systems, and commercial building central air handling units.
Quality verification begins with our CNAS-accredited laboratory, which issues test reports for efficiency, dust holding capacity, and resistance. These reports provide documented performance data for each filter type, supporting your validation process.
Production is governed by IQC, IPQC, and OQC procedures: incoming materials are inspected, in-process checks monitor critical parameters, and outgoing filters are tested before shipment. Zanxis holds IATF 16949 (achieved in 2024) and ISO 9001, ISO 14001, and ISO 45001 certifications. The manufacturing facility covers 50,000 m², including six cleanrooms totalling 20,000 m², where filters are assembled under controlled conditions. With over 20 years of experience and more than 1,000 filter solutions developed, we support OEM/ODM projects with custom sizes, efficiencies, frame materials, logos, and packaging. Our location is Zhongshan, Guangdong, China.
To request samples, test reports, or a quotation, please provide the following details:
Submit your requirements through our contact page and our technical team will respond with a tailored proposal.
Yes. Zanxis has its own CNAS-accredited laboratory that issues test reports for efficiency, dust holding capacity, and resistance. Each report is specific to the filter model and can be provided with samples or production orders.
For standard specifications, samples are typically available within 5–7 working days. Custom samples may take 15–25 working days depending on complexity. The validation process includes sample preparation, testing, and reporting, and we can adjust the timeline based on your project schedule.
The Zanxis V-type filter is available in efficiency classes from M6 to H14, covering medium to high efficiency requirements. The specific class depends on the media grade selected, and we can provide test data for the chosen class.
Yes. We offer full OEM/ODM customisation, including non-standard sizes, frame materials (ABS plastic or galvanized iron), efficiency classes, and airflow ratings. Provide your specifications and we will propose a design that fits your system.
MOQ for standard sizes is typically 10 pieces, allowing for sample testing. For customised filters, MOQ is generally 50–100 pieces, depending on the design. Please contact us with your requirements for a precise quote.
Standard stock items ship within 5–7 working days. Custom orders require 15–25 working days after drawing approval. For large-volume orders, we can schedule deliveries in batches to meet your project timeline.
Replacement interval depends on operating conditions and pre-filtration. A common guideline is to replace when the final resistance reaches twice the initial resistance, typically around 500–600 Pa, or when airflow drops below 85% of design value. We can help you establish a maintenance schedule based on your system.
Yes. We encourage sample testing. For standard sizes, we can provide 1–2 free samples (freight collect). Custom samples are quoted based on complexity, and the sample fee is deductible from the order. Each sample includes a test report for verification.